{"id":1956,"date":"2018-04-05T14:30:51","date_gmt":"2018-04-05T13:30:51","guid":{"rendered":"http:\/\/mevoco.be\/en\/?page_id=1956"},"modified":"2019-02-07T14:23:22","modified_gmt":"2019-02-07T13:23:22","slug":"load-break-switches-and-mechanical-drives","status":"publish","type":"page","link":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/","title":{"rendered":"Load break switches and mechanical drives"},"content":{"rendered":"<div class=\"flex_column av_one_full  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><div style='padding-bottom:10px;' class='av-special-heading av-special-heading-h2   '><h2 class='av-special-heading-tag'  itemprop=\"headline\"  >Load break switches and mechanical drives<\/h2><div class='special-heading-border'><div class='special-heading-inner-border' ><\/div><\/div><\/div><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_1' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading   '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV64 Load break switch (On\/Off\/Earth)<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p>The RV64 is a SF<sub>6<\/sub>-gas insulated compact submersible unit with load break switch and earthing switches on both sides of the load break switch. So both sides of the unit can be earthed. There is an interlock between earthing switches and load break swith. The unit is submersible at a dept of 3 m. The manual opening of the load break switch can be performed when fully submersed. The unit serves for application at 12 kV with a nominal current of 200 A. There are sight glasses for the position indication of the switches. A gas density SF<sub>6\u00a0<\/sub>meter is present.<\/p>\n<p><strong style=\"color: black;\">The unit is constituted by :<\/strong><\/p>\n<ul>\n<li>Three-phase three position load break switch RV 50 of the class E3, M1 according to IEC 62271-103, 17,5 kV \u2013 630 A \u2013 20 kA and earthing switch with a making capacity of 50 kA.<\/li>\n<li>Three-phase earthing switch RV 50 of the class E2, M1 according to IEC 62271-103, 17,5 kV \u2013 630 A \u2013 20 kA, with a making capacity of 50 kA.<\/li>\n<li>Interlock between earthing switches and load break switch.<\/li>\n<li>Stainless steel tank filled with SF6 at 0.15 MPa.<\/li>\n<\/ul>\n<p><strong style=\"color: black;\">The advantages :<\/strong><\/p>\n<ul>\n<li>Maintenance friendly and fully integrated load break switch and earthing switches on both sides.<\/li>\n<li>Both sides of the unit can be earthed.<\/li>\n<li>Fully submersible.<\/li>\n<li>Sight glasses for the position indication.<\/li>\n<li>Gass density SF6 meter.<\/li>\n<\/ul>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2018\/04\/Mevoco-Flyer-RV64-EN-DW640318-1.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUE<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2019\/02\/Mevoco-User-manual-RV64-DW643218.pdf\" target=\"_blank\" rel=\"noopener\">USER MANUAL<\/a><\/div>\n<\/div><\/section><\/p><\/div><div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div style='height:50px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/07\/MEVOCO-RV64.png' alt='' title='MEVOCO-RV64'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/p><\/div><\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_1' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'><div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><\/p>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_2' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/04\/MEVOCO-RV-44-square.png' alt='' title='MEVOCO-RV 44 (square)'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading  '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV44 Load break switch (On\/Off)<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p>The RV44 load break switch consists of an epoxy enclosure in which fixed and movable contacts are mounted. The switch is filled with SF<sub>6<\/sub>-gas (sulphur hexafluoride) and sealed for life. The special properties of the SF<sub>6<\/sub>-gas guarantee a perfect insulating and\u00a0<strong>reliable quenching<\/strong><span class=\"Apple-converted-space\">\u00a0<\/span>in the housing function. As a result of the ideal switching speed at the switch\/drive-mechanism combination, the load-break switch features very short arc times. The patented switching principle combines maximum gas revolving effect with a precise finishing of the electrical contacts. This guarantees excellent <strong>dielectrical<\/strong> features and a minimum of contact erosion. The load break switch is a two-position switch that connects or interrupts the voltage between the high voltage cables and the bus bar. The position of the load-break switch is clearly indicated in the single line diagram. Depending on the version, the load break switch is operated manually or electrically. <strong>See Drive Mechanism.<\/strong> Manual operation is carried out by means of the supplied operating handle.<\/p>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2017\/03\/MEVOCO-Folder-RV44-EN-DW440316.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUE<\/a><\/div>\n<\/div><\/section><\/p><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_2' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_3' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading  '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV50 Load break switch (On\/Off\/Earth)<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p>The three-position switch RV50 (on\/off\/earth) is tested in accordance with IEC standards. The concept ensures a natural interlock (open, closed, grounded) of the primary functions of the cubicle. A short bow time by optimizing the speed of the mechanical drive and a patented combines with a SF<sub>6<\/sub>-gas rotation and electrical contacts for the extinction of the arc. Our experience with the RV44 switch from the DF-2 range, finds a perfect application here. The switch is of the class E3\/M1 (100 CO and 1000 mechanical operations) according to IEC 62271-102.<\/p>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2018\/04\/Mevoco-Flyer-RV-50-EN-DW500318.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUE<\/a><\/div>\n<\/div><\/section><\/p><\/div><div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/08\/Mevoco-RV50_square-300x300.png' alt='' title='Mevoco-RV50_square'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_3' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_4' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/04\/MEVOCO-RV-53-square.png' alt='' title='MEVOCO-RV 53 (square)'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading  '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV53 Load break switch (On\/Off\/Earth)<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p>The RV53 is a with SF<sub>6<\/sub>-gas-filled, 3-phase (in\/out\/earth) load-break switch of the E3 class according to IEC 60265-1 to 24 kV \u2013 630(A) \u2013 20 kA. It is a product for integration in locally manufactured switchingdistribution and control apparatus (OEM) with the matching mechanical drives.<\/p>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2017\/03\/MEVOCO-Folder-RV53-EN-DW530316.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUE<\/a><\/div>\n<\/div><\/section><\/p><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_4' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_5' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading   '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV53 Load break switch assemblies for OEM<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p>The RV53 load break switch assemblies feature DA or DP drive mechanisms and housing with mimic diagram directly mounted onto the switch. The compact assembly can be directly mounted into medium voltage switchgear.<\/p>\n<p>RV53 is a three-position SF<sub>6<\/sub>-gas insulated \u201csealed for life\u201d load break switch with integrated earth. Its \u201cbuilt to last\u201d design with double seals is maintenance free. The concept is safe and robust. It is focused on reliable operation during the full life time of medium voltage switchgear. It features an integrated earth. The switch enclosure consists of two half-shells in high quality epoxy material. The shell design features isolating epoxy walls that protect phases from flash over.<\/p>\n<p>DA is a double spring drive mechanism for operator independent switching between open, closed or earthed position of the RV switch in incoming\/outgoing functions.<\/p>\n<p>DP is a three spring drive mechanism for operator independent switching. It is designed for use in combination with fuses.<\/p>\n<p>DA and DP have standard integrated functional interlocks to prevent incorrect operations.<\/p>\n<p>DA and DP are fit to receive plug &amp; play accessories to cover a wide range of applications.<\/p>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2018\/04\/Mevoco-Brochure-RV53-OEM-EN-DW535317.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUE<\/a><\/div>\n<\/div><\/section><\/p><\/div><div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div style='height:50px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/08\/Mevoco-RV53DA_square-300x300.png' alt='' title='Mevoco-RV53DA_square'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/p><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_5' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_6' class='avia-section main_color avia-section-default avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div class=\"flex_column av_one_third  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/04\/MEVOCO-RV-54-square.png' alt='' title='MEVOCO-RV 54 (square)'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><\/div><div class=\"flex_column av_two_third  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div style='padding-bottom:10px;color:#009ee3;' class='av-special-heading av-special-heading-h4 custom-color-heading  '><h4 class='av-special-heading-tag'  itemprop=\"headline\"  >RV54 Load break switch<\/h4><div class='special-heading-border'><div class='special-heading-inner-border' style='border-color:#009ee3'><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><section class=\"av_textblock_section\">\n<div class=\"avia_textblock \">\n<p>Its <strong>ability to be totally immersed<\/strong> (tested on water column 7 m) makes the RV54 perfectly usable in installations where there is flooding risk. The load break switch is ideal for separating and sectioning off power to select parts of your network.<\/p>\n<p>Technical characteristics :<\/p>\n<ul>\n<li>rated current : 900(A).<\/li>\n<li>breaking current : 900(A).<\/li>\n<li>hold current of 40 k\/2 sec.<\/li>\n<li>create flow of 106k\u00c2 (5 x C).<\/li>\n<\/ul>\n<\/div>\n<\/section>\n<\/div><\/section><br \/>\n<div style='height:20px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><div style=\"padding-right: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"https:\/\/mevoco.be\/contact\/\" target=\"_blank\" rel=\"noopener\">CONTACT US<\/a><\/div>\n<div style=\"padding-left: 10px; float: left;\"><a class=\"avia-button avia-icon_select-no avia-color-theme-color avia-position-left\" href=\"http:\/\/www.het-veer.be\/en\/wp-content\/uploads\/sites\/3\/2017\/03\/MEVOCO-Folder-RV54-EN-DW540316.pdf\" target=\"_blank\" rel=\"noopener\">DOWNLOAD CATALOGUS<\/a><\/div>\n<\/div><\/section><\/p><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_6' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='av_section_7' class='avia-section main_color avia-section-no-padding avia-no-border-styling avia-bg-style-scroll  container_wrap sidebar_right' style = 'background-color: #f6f6f6; '  ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n<div style='height:50px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div>\n<div class=\"flex_column av_one_fifth  flex_column_div av-zero-column-padding first  \" style='border-radius:0px; '><\/div><div class=\"flex_column av_three_fifth  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><p><div class='avia-image-container  av-styling-   avia-align-center '  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\"  ><div class='avia-image-container-inner'><img class='avia_image ' src='https:\/\/mevoco.be\/en\/wp-content\/uploads\/sites\/7\/2018\/03\/made-to-measure.png' alt='' title='made to measure'   itemprop=\"thumbnailUrl\"  \/><\/div><\/div><br \/>\n<div style='padding-bottom:10px;' class='av-special-heading av-special-heading-h3  blockquote modern-quote modern-centered  '><h3 class='av-special-heading-tag'  itemprop=\"headline\"  >WE BUILD MADE TO MEASURE.<\/h3><div class='special-heading-border'><div class='special-heading-inner-border' ><\/div><\/div><\/div><br \/>\n<section class=\"av_textblock_section\"  itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock '   itemprop=\"text\" ><p style=\"text-align: center;\">Mevoco&#8217;s R&amp;D department has a lot of experience building <strong>made to measure solutions<\/strong>. Some of our best products were built <strong>co-engineering with our clients<\/strong>.<\/p>\n<\/div><\/section><br \/>\n<div style='height:10px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div><br \/>\n<div class='avia-button-wrap avia-button-center '><a href='https:\/\/mevoco.be\/en\/contact\/' class='avia-button  avia-icon_select-no avia-color-theme-color avia-size-medium avia-position-center '   ><span class='avia_iconbox_title' >CONTACT OUR ENGINEERS<\/span><\/a><\/div><\/p><\/div><div class=\"flex_column av_one_fifth  flex_column_div av-zero-column-padding   \" style='border-radius:0px; '><\/div><div style='height:50px' class='hr hr-invisible '><span class='hr-inner ' ><span class='hr-inner-style'><\/span><\/span><\/div>\n<\/div><\/div><\/div><!-- close content main div --><\/div><\/div><div id='after_section_7' class='main_color av_default_container_wrap container_wrap sidebar_right'   ><div class='container' ><div class='template-page content  av-content-small alpha units'><div class='post-entry post-entry-type-page post-entry-1956'><div class='entry-content-wrapper clearfix'>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1956","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Load break switches and mechanical drives - Mevoco EN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Load break switches and mechanical drives - Mevoco EN\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/\" \/>\n<meta property=\"og:site_name\" content=\"Mevoco EN\" \/>\n<meta property=\"article:modified_time\" content=\"2019-02-07T13:23:22+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"19 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/\",\"url\":\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/\",\"name\":\"Load break switches and mechanical drives - Mevoco EN\",\"isPartOf\":{\"@id\":\"https:\/\/mevoco.be\/en\/#website\"},\"datePublished\":\"2018-04-05T13:30:51+00:00\",\"dateModified\":\"2019-02-07T13:23:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/#breadcrumb\"},\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/mevoco.be\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Load break switches and mechanical drives\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/mevoco.be\/en\/#website\",\"url\":\"https:\/\/mevoco.be\/en\/\",\"name\":\"Mevoco EN\",\"description\":\"One-stop medium voltage shop\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/mevoco.be\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-AU\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Load break switches and mechanical drives - Mevoco EN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/","og_locale":"en_US","og_type":"article","og_title":"Load break switches and mechanical drives - Mevoco EN","og_url":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/","og_site_name":"Mevoco EN","article_modified_time":"2019-02-07T13:23:22+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"19 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/","url":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/","name":"Load break switches and mechanical drives - Mevoco EN","isPartOf":{"@id":"https:\/\/mevoco.be\/en\/#website"},"datePublished":"2018-04-05T13:30:51+00:00","dateModified":"2019-02-07T13:23:22+00:00","breadcrumb":{"@id":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/#breadcrumb"},"inLanguage":"en-AU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/mevoco.be\/en\/load-break-switches-and-mechanical-drives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/mevoco.be\/en\/"},{"@type":"ListItem","position":2,"name":"Load break switches and mechanical drives"}]},{"@type":"WebSite","@id":"https:\/\/mevoco.be\/en\/#website","url":"https:\/\/mevoco.be\/en\/","name":"Mevoco EN","description":"One-stop medium voltage shop","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mevoco.be\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-AU"}]}},"_links":{"self":[{"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/pages\/1956","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/comments?post=1956"}],"version-history":[{"count":44,"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/pages\/1956\/revisions"}],"predecessor-version":[{"id":3295,"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/pages\/1956\/revisions\/3295"}],"wp:attachment":[{"href":"https:\/\/mevoco.be\/en\/wp-json\/wp\/v2\/media?parent=1956"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}